ROS Assay Protocol
Thursday, 9/16/2021
Material
●
MQ
●
HRP
●
Luminol or LO/12
●
Elicitor
●
Leaf disks
●
96-well plate
●
Falcon tubes (one per elicitor + 2)
●
flg-22 (positive control)
●
Plastik thingy for multipipette
Protocol
●
Grow plants
●
Take leaf disks
●
Fill one row of the 96-well plate per elicitor with 100 μl MQ and add one leaf disk per well
●
Cover in aluminium foil and let rest over night (in the dark)
●
Cover all falcon tubes in aluminium foil before adding luminol or Lo/12
●
Preparing the ROS solution:
○
2ml MilliQ H2O per row of
○
2miL HRP
○
2miL luminol | LO/12 (needs to be kept dark)
○
add everything to small falcon tubes
○
decide on concentration of elicitor and add elicitor (one per falcon tube)
●
Take out the 100 ml MQ of each well
●
Go to the plate reader and add the ROS solution to the well plate there.